Skip to content

Construction ID:

Floor Finishes: Carpet, tiles, timber, laminates, synthetics.

Construction Height:

 100–150¹

mm

Mass:

 37–43¹

kg / m²

Thermal Resistance (R-value):

 0.55²

m² K / W

Uniform Distributed Load (UDL):

2.0

kN / m²

Point Load (≥ 20 cm²):

1.5

kN

Impact Sound Reduction:

dB

¹ Based on 50 mm and 100 mm Foamglass, and excludes floor finish.
² R-value of JUPITER Ideal system only.

Area of Application:

  • Ground floors or floors located above unheated rooms such as garages and basements.
  • For upper floor installations refer instead to Construction ID: STR-10U.

Additional Information:

  • Substrate must be solid, level and flat so that the heating elements can lie flat. Tolerance required as per Surface Regularity 1 (± 3 mm over 2 m).
  • Installation environment must be at least 10°C and at most 40°C.
  • Fermacell elements are glued and screwed or stapled together as a floating floor.
  • Fermacell Product Format: 1500 x 500 x 20 mm.
  • CAUTION: Restrictions apply to maximum tile and stone sizes on Fermacell.

Floor Finishes:

Carpet, tiles, timber, laminates, synthetics.

Construction Height:

 100–150¹ mm

Mass:

 37–43¹ kg / m²

Thermal Resistance (R-value):

 0.55² m² K / W

Uniform Distributed Load (UDL):

2.0 kN / m²

Point Load (≥ 20 cm²):

– kN

Impact Sound Reduction:

– dB

¹ Based on 50 mm and 100 mm Foamglass, and excludes floor finish.
² R-value of JUPITER Ideal system only.

Area of Application:

  • Ground floors or floors located above unheated rooms such as garages and basements.
  • For upper floor installations refer instead to Construction ID: STR-10U.

Additional Information:

  • Substrate must be solid, level and flat so that the heating elements can lie flat. Tolerance required as per Surface Regularity 1 (± 3 mm over 2 m).
  • Installation environment must be at least 10°C and at most 40°C.
  • Fermacell elements are glued and screwed or stapled together as a floating floor.
  • Fermacell Product Format: 1500 x 500 x 20 mm.
  • CAUTION: Restrictions apply to maximum tile and stone sizes on Fermacell.