Skip to content

Construction ID:

Floor Finishes: All Floor Finishes (Caution with Tiles and Stone)

Construction Height:

 20¹

mm

Mass:

 27 – 29²

kg / m²

Thermal Resistance (R-value):

 3.379³

m² K / W

Uniform Distributed Load (UDL):

 2.0⁴

kN / m²

Point Load (≥ 20 cm²):

 2.0⁴

kN

Impact Sound Reduction:

dB

¹ Construction height based on Fermacell thickness.
² Based on 50 mm and 100 mm Kingspan Kooltherm K103, excludes floor finish.
³ R-value of Jupiter Ideal system only, Part L compliant with the correct amount of additional insulation.
⁴ Dependent on joist integrity.

Area of Application:

  • Ground floors or floors located above unheated or uninsulated rooms such as garages and basements.
  • For upper floor installations refer instead to Construction ID: EPS-BJ3U.

Additional Information:

  • When installed, the Fermacell elements may follow any undulation that occurs from the joists. This may need to be taken out with the use of a thin levelling compound.
  • Aluminium diffuser plates should be flush with the top of the joists.

Floor Finishes:

All Floor Finishes (Caution with Tiles and Stone)

Construction Height:

 20¹ mm

Mass:

 27 – 29² kg / m²

Thermal Resistance (R-value):

 3.379³ m² K / W

Uniform Distributed Load (UDL):

 2.0⁴ kN / m²

Point Load (≥ 20 cm²):

– kN

Impact Sound Reduction:

– dB

¹ Construction height based on Fermacell thickness.
² Based on 50 mm and 100 mm Kingspan Kooltherm K103, excludes floor finish.
³ R-value of Jupiter Ideal system only, Part L compliant with the correct amount of additional insulation.
⁴ Dependent on joist integrity.

Area of Application:

  • Ground floors or floors located above unheated or uninsulated rooms such as garages and basements.
  • For upper floor installations refer instead to Construction ID: EPS-BJ3U.

Additional Information:

  • When installed, the Fermacell elements may follow any undulation that occurs from the joists. This may need to be taken out with the use of a thin levelling compound.
  • Aluminium diffuser plates should be flush with the top of the joists.