Construction ID:
Floor Finishes: Adhered Timber, Tiles
Construction Height:
92 – 142¹
mm
Mass:
25 – 27¹
kg / m²
Thermal Resistance (R-value):
0.86²
m² K / W
Uniform Distributed Load (UDL):
4.0³
kN / m²
Point Load (≥ 20 cm²):
3.5³
kN
Impact Sound Reduction:
–
dB
¹ Based on 50 mm and 100 mm Kingspan Kooltherm K103, excludes floor finish.
² R-value of JUPITER Ideal system only.
³ Tested with Kingspan Kooltherm K103 ≤ 100 mm.
Area of Application:
- Ground floors or floors located above unheated rooms such as garages and basements.
- For upper floor installations refer instead to Construction ID: EPS-70U.
Additional Information:
- Substrate must be solid, level and flat so that the heating elements can lie flat. Tolerance required as per Surface Regularity 1 (± 3 mm over 2 m).
- Installation Environment must be at least 12°C and at most 30°C.
- Firmax CP Product Format: 1200 x 600 x 12 mm (2 layers of 6 mm).
- Firmax CP Mass: 21 kg / m².
- Firmax CP Thermal Resistance: 0.038 m² K / W.
Floor Finishes:
Adhered Timber, Tiles
Construction Height:
92 – 142¹ mm
Mass:
25 – 27¹ kg / m²
Thermal Resistance (R-value):
0.86² m² K / W
Uniform Distributed Load (UDL):
4.0³ kN / m²
Point Load (≥ 20 cm²):
– kN
Impact Sound Reduction:
– dB
¹ Based on 50 mm and 100 mm Kingspan Kooltherm K103, excludes floor finish.
² R-value of JUPITER Ideal system only.
³ Tested with Kingspan Kooltherm K103 ≤ 100 mm.
Area of Application:
- Ground floors or floors located above unheated rooms such as garages and basements.
- For upper floor installations refer instead to Construction ID: EPS-70U.
Additional Information:
- Substrate must be solid, level and flat so that the heating elements can lie flat. Tolerance required as per Surface Regularity 1 (± 3 mm over 2 m).
- Installation Environment must be at least 12°C and at most 30°C.
- Firmax CP Product Format: 1200 x 600 x 12 mm (2 layers of 6 mm).
- Firmax CP Mass: 21 kg / m².
- Firmax CP Thermal Resistance: 0.038 m² K / W.