Construction ID:

Floor Finishes: Carpet, Tiles, Timber, Laminates, Synthetics

Construction Height:

 98 – 148¹

mm

Mass:

 40 – 42¹

kg / m²

Thermal Resistance (R-value):

 0.86²

m² K / W

Uniform Distributed Load (UDL):

 5.0³

kN / m²

Point Load (≥ 20 cm²):

 4.0³

kN

Impact Sound Reduction:

dB

¹ Based on 50 mm and 100 mm Kingspan Kooltherm K103, excludes floor finish.
² R-value of JUPITER Ideal system only.
³ Tested with Kingspan Kooltherm K103 ≤ 100 mm.

Area of Application:

  • Ground floors or floors located above unheated rooms such as garages and basements.
  • For upper floor installations refer instead to Construction ID: EPS-40U.

Additional Information:

  • Substrate must be solid, level and flat so that the heating elements can lie flat. Tolerance required as per Surface Regularity 1 (± 3 mm over 2 m).
  • Installation Environment must be at least 5°C.
  • SRT Product Format: 600 x 250 x 18 mm.

Floor Finishes:

Carpet, Tiles, Timber, Laminates, Synthetics

Construction Height:

 98 – 148¹ mm

Mass:

 40 – 42¹ kg / m²

Thermal Resistance (R-value):

 0.86² m² K / W

Uniform Distributed Load (UDL):

 5.0³ kN / m²

Point Load (≥ 20 cm²):

– kN

Impact Sound Reduction:

– dB

¹ Based on 50 mm and 100 mm Kingspan Kooltherm K103, excludes floor finish.
² R-value of JUPITER Ideal system only.
³ Tested with Kingspan Kooltherm K103 ≤ 100 mm.

Area of Application:

  • Ground floors or floors located above unheated rooms such as garages and basements.
  • For upper floor installations refer instead to Construction ID: EPS-40U.

Additional Information:

  • Substrate must be solid, level and flat so that the heating elements can lie flat. Tolerance required as per Surface Regularity 1 (± 3 mm over 2 m).
  • Installation Environment must be at least 5°C.
  • SRT Product Format: 600 x 250 x 18 mm.