Construction ID:
Floor Finishes: All Floor Finishes
Construction Height:
18¹
mm
Mass:
43²
kg / m²
Thermal Resistance (R-value):
0.75
m² K / W
Uniform Distributed Load (UDL):
5.0³
kN / m²
Point Load (≥ 20 cm²):
5.0³
kN
Impact Sound Reduction:
–
dB
¹ Construction height based on SRT thickness.
² Excludes floor finish.
³ Dependent on joist integrity.
Area of Application:
- Floors with rooms of equal temperature above and below, and a minimum R-value of 0.75 m² K / W.
- This construction is suitable for use on intermediate floors, no further insulation is needed to meet the Part L requirements.
- For ground floor installations refer to Construction ID: ECO-BJ2G.
Additional Information:
- When installed, the Screed Replacement Tile (SRT) may follow any undulation that occurs from the joists. This may need to be taken out with the use of a thin levelling compound.
- Aluminium diffuser plates should be flush with the top of the joists.
Floor Finishes:
All Floor Finishes
Construction Height:
18¹ mm
Mass:
43² kg / m²
Thermal Resistance (R-value):
0.75 m² K / W
Uniform Distributed Load (UDL):
5.0³ kN / m²
Point Load (≥ 20 cm²):
– kN
Impact Sound Reduction:
– dB
¹ Construction height based on SRT thickness.
² Excludes floor finish.
³ Dependent on joist integrity.
Area of Application:
- Floors with rooms of equal temperature above and below, and a minimum R-value of 0.75 m² K / W.
- This construction is suitable for use on intermediate floors, no further insulation is needed to meet the Part L requirements.
- For ground floor installations refer to Construction ID: ECO-BJ2G.
Additional Information:
- When installed, the Screed Replacement Tile (SRT) may follow any undulation that occurs from the joists. This may need to be taken out with the use of a thin levelling compound.
- Aluminium diffuser plates should be flush with the top of the joists.