[eco-50g]
Construction ID:
Download Specification
Floor Finishes: Carpet, tiles, timber, laminates, synthetics.
Construction Height:
83–133¹
mm
Mass:
19–25¹
kg / m²
Thermal Resistance (R-value):
0.75²
m² K / W
Uniform Distributed Load (UDL):
2.0
kN / m²
Point Load (≥ 20 cm²):
2.0
kN
Impact Sound Reduction:
–
dB
¹ Based on 50 mm and 100 mm Foamglas, and excludes floor finish.
² R-value of JUPITER Ideal system only.
Area of Application:
- Ground floors or floors located above unheated rooms such as garages and basements.
- For upper floor installations refer instead to Construction ID: ECO-50U.
Additional Information:
- Substrate must be solid, level and flat so that the heating elements can lie flat. Tolerance required as per Surface Regularity 1 (± 3 mm over 2 m).
- Installation environment must be at least 5°C and at most 30°C.
Floor Finishes:
Carpet, tiles, timber, laminates, synthetics.
Construction Height:
83–133¹ mm
Mass:
19–25¹ kg / m²
Thermal Resistance (R-value):
0.75² m² K / W
Uniform Distributed Load (UDL):
2.0 kN / m²
Point Load (≥ 20 cm²):
– kN
Impact Sound Reduction:
– dB
¹ Based on 50 mm and 100 mm Foamglas, and excludes floor finish.
² R-value of JUPITER Ideal system only.
Area of Application:
- Ground floors or floors located above unheated rooms such as garages and basements.
- For upper floor installations refer instead to Construction ID: ECO-50U.
Additional Information:
- Substrate must be solid, level and flat so that the heating elements can lie flat. Tolerance required as per Surface Regularity 1 (± 3 mm over 2 m).
- Installation environment must be at least 5°C and at most 30°C.