Skip to content

Construction ID:

Floor Finishes: Engineered Timber

Construction Height:

 80 – 130¹

mm

Mass:

 14 – 20¹

kg / m²

Thermal Resistance (R-value):

 0.75²

m² K / W

Uniform Distributed Load (UDL):

2.0

kN / m²

Point Load (≥ 20 cm²):

1.0

kN

Impact Sound Reduction:

dB

¹ Based on 50 mm and 100 mm Kingspan Kooltherm K103, excludes floor finish.
² R-value of JUPITER Ideal system only.

Area of Application:

  • Ground floors or floors located above unheated rooms such as garages and basements.
  • For upper floor installations refer instead to Construction ID: ECO-20U.

Additional Information:

  • Substrate must be solid, level and flat so that the heating elements can lie flat. Tolerance required as per Surface Regularity 1 (± 3 mm over 2 m).

Floor Finishes:

Engineered Timber

Construction Height:

 80 – 130¹ mm

Mass:

 14 – 20¹ kg / m²

Thermal Resistance (R-value):

 0.75² m² K / W

Uniform Distributed Load (UDL):

2.0 kN / m²

Point Load (≥ 20 cm²):

– kN

Impact Sound Reduction:

– dB

¹ Based on 50 mm and 100 mm Kingspan Kooltherm K103, excludes floor finish.
² R-value of JUPITER Ideal system only.

Area of Application:

  • Ground floors or floors located above unheated rooms such as garages and basements.
  • For upper floor installations refer instead to Construction ID: ECO-20U.

Additional Information: