Construction ID:

Floor Finishes: Carpet, Tile, Timber, Laminates, Synthetics

Construction Height:

 50¹

mm

Mass:

 31¹

kg / m²

Thermal Resistance (R-value):

0.75

m² K / W

Uniform Distributed Load (UDL):

1.5

kN / m²

Point Load (≥ 20 cm²):

1.0

kN

Impact Sound Reduction:

<28

dB

¹ Excludes floor finish.

Area of Application:

  • Floors with rooms of equal temperature above and below, and a minimum R-value of 0.75 m² K / W.
  • This construction is suitable for use on intermediate floors, no further insulation is needed to meet the requirements of Approved Document L.
  • For ground floor installations refer to Construction ID: ECO-10G.

Additional Information:

  • Substrate must be solid, level and flat so that the heating elements can lie flat. Tolerance required as per Surface Regularity 1 (± 3 mm over 2 m).
  • Fermacell elements are glued and screwed or stapled together as a floating floor.
  • Installation environment must be at least 10°C and at most 40°C.
  • Fermacell Product Format: 1500 mm x 500 mm x 20 mm.
  • Caution: restrictions apply to maximum tile and stone sizes on Fermacell.

Floor Finishes:

Carpet, Tile, Timber, Laminates, Synthetics

Construction Height:

 50¹ mm

Mass:

 31¹ kg / m²

Thermal Resistance (R-value):

0.75 m² K / W

Uniform Distributed Load (UDL):

1.5 kN / m²

Point Load (≥ 20 cm²):

<28 kN

Impact Sound Reduction:

<28 dB

¹ Excludes floor finish.

Area of Application:

  • Floors with rooms of equal temperature above and below, and a minimum R-value of 0.75 m² K / W.
  • This construction is suitable for use on intermediate floors, no further insulation is needed to meet the requirements of Approved Document L.
  • For ground floor installations refer to Construction ID: ECO-10G.

Additional Information:

  • Substrate must be solid, level and flat so that the heating elements can lie flat. Tolerance required as per Surface Regularity 1 (± 3 mm over 2 m).
  • Fermacell elements are glued and screwed or stapled together as a floating floor.
  • Installation environment must be at least 10°C and at most 40°C.
  • Fermacell Product Format: 1500 mm x 500 mm x 20 mm.
  • Caution: restrictions apply to maximum tile and stone sizes on Fermacell.